Network

Follow a connection to trace an asset upstream or downstream.

Upstream connections

Illustrative machine system

Closed-loop circulation pump

Fictional asset P-01. All readings and service entries are illustrative.

Asset sources

Downstream connections

My lifecycle records

Operating and service history

Fictional asset P-01. All readings and service entries are illustrative.

At the motor and pump boundary, electricity and return water enter. Water leaves the discharge and circulates back through the same loop.

Log as of UTC.

UTC UTC
  1. Morning circulation

    – UTC

    A snapshot captured input power, inlet and discharge pressure, and loop flow.

    Recorded readings (4)
    Input · Electrical power · Motor supply
    52 W · UTC
    Input · Gauge pressure · Return inlet
    130 kPa · UTC
    Output · Gauge pressure · Pump discharge
    148 kPa · UTC
    Output · Water flow · Pump discharge
    24 L/min · UTC
  2. Connector inspection

    – UTC

    The service log records a stop and an external connector inspection. The connector stayed in place.

    Previous entry · Morning circulation

  3. Circulation resumed

    – UTC

    A second snapshot followed the return to service.

    Recorded readings (4)
    Input · Electrical power · Motor supply
    51 W · UTC
    Input · Gauge pressure · Return inlet
    130 kPa · UTC
    Output · Gauge pressure · Pump discharge
    147 kPa · UTC
    Output · Water flow · Pump discharge
    23.5 L/min · UTC

    Previous entry · Connector inspection

  4. Flowmeter verification

    – UTC

    The service plan reserves this interval to compare the meter reading with a reference.

    Previous entry · Circulation resumed